Technical Info
Sauna Specifications
| Arch Covers | Nordic spruce (painted) Nordic spruce (unpainted) | 
|---|---|
| Backrest | Optional | 
| Bench Material | Thermo alder Thermo aspen Thermo pine | 
| Drain | Yes | 
| Floor Grate | Nordic spruce Thermowood | 
| Heater Guard | Thermowood | 
| Compatible Heater | Electric | 
| Height (cm) | 210 | 
| Staves Thickness (mm) | 42 | 
| Ventilation | Air vents | 
| Wall Thickness (mm) | 28 | 
| Roof Cover | Black shingles | 
| Sauna Shape | Cube sauna | 
| Capacity (persons) | 4 5 6 | 
| Rooms | 1 room | 
| Diameter | – | 
| Place of Use | Outdoor | 
| Length (cm) | 280 | 
The electrical supply you need depends on the kW rating of your sauna heater. We strongly recommend speaking with a qualified electrician before starting any installation.
Most home saunas in the UK use a dedicated power supply, similar to what’s used for an electric shower or cooker. Domestic sauna heaters typically run on a single-phase 230V supply.
To work out the electrical current (Amps), use this formula:
Watts ÷ Volts = Amps
Example:
  6kW (6000W) ÷ 230V = approximately 26 Amps
Typical Guide for Domestic Sauna Heaters
| Heater Power | Current Draw | Suggested Cable Size (Single-Phase) | 
|---|---|---|
| 2.3 kW | 10 Amps | 1.5 mm² | 
| 3.0 kW | 13 Amps | 2.5 mm² | 
| 3.6 kW | 15 Amps | 2.5 mm² | 
| 4.5 kW | 19 Amps | 2.5–4.0 mm² | 
| 6.0 kW | 26 Amps | 4.0 mm² | 
| 8.0 kW | 35 Amps | 6.0 mm² | 
| 9.0 kW | 40 Amps | 6.0 mm² (or larger, depending on distance) | 
Important Notes
- Cable size depends on cable length, installation method, and other on-site factors.
- Always follow the advice of a qualified electrician.
- All installations must comply with current UK wiring standards (BS 7671).